IP 68 rating
(48 hr @ 1 m [3.28 ft] under water
Graphical Monochrome Display
63.5 mm (2.5 in)
Maintainability
(brass bar mounting)
In face conveyor or plow automation systems the HBT PMC-V provides the human machine interface (HMI) to interact with the PMC-D drive controls to operate manual mode, visualize and change parameters and show actual process values. Within a PMC-D system minimum one and typically up to 3 PMC-Vs are in equal operation.
Electrical Data | ||
| Parameter | Typical Value | Maximum Ratings |
| Supply Voltage | 12V DC | 9V–13.2V |
| Power Supply Current | 1 A | 1.5 A |
Environmental Data | ||
| Parameter | Typical Value | Maximum Ratings |
| Temperature (Tamb) | 20° C (68° F) | –20° C – +40° C (–4° F – +104° F) |
| Socket | Pin 1 | Pin 2 | Pin 3 | Pin 4 |
|---|---|---|---|---|
| St1 | Optocoupler Anode | Relay Contact NO: a | Relay Contact NO: b | Optocoupler Kathode |
| St2 | +12 V (A) | Serial Interface: RxD | Serial Interface: TxD | GND |
| St3 | +12 V (B) | Serial Interface: RxD | Serial Interface: TxD | GND |
| St4 | +12 V (C) | Serial Interface: RxD | Serial Interface: TxD | GND |
| St5 | Options | Options | Options | Options |
| St6 | Profibus: a (internal) | Profibus: b (internal) | ||
| St7 | +12 V Input | Serial Interface: TxD | Serial Interface: RxD | GND Input |
| St8 | +12 V (B) | Measurement Input 1 | +8.2 V | GND |
| St9 | +12 V (C) | Measurement Input 2 | +8.2 V | GND |
| St10 | +12 V (A) | Measurement Input 3 | +8.2 V | GND |
| St11 | Options | Options | Options | Options |
| St12 | Profibus: a (internal) | Profibus: b (internal) |
The designations of the options equal the second and third to last characters of the type designation listed on the equipment.
| Option | Socket | Pin 1 | Pin 2 | Pin 3 | Pin 4 |
|---|---|---|---|---|---|
| ** | St5 | ||||
| St11 | |||||
| AB | St5 | Profibus: a (external) | Profibus: b (external) | ||
| St11 | Profibus: a (external) | Profibus: b (external) |
You need further product information or like to request a quote?